產品中心
簡要描述:漢密爾頓Hamilton哈美頓79433/79448 PRP-X100 Hamilton食品總砷無機砷檢測陰離子液相色譜柱 4.1mmx250mm 10um;Hamilton PRP-X100 Hamilton食品總砷無機砷檢測陰離子液相色譜柱79433/79448
詳細介紹
品牌 | 其他品牌 | 貨號 | 79433/79448 |
---|---|---|---|
規(guī)格 | 4.1mmx250mm 10um | 供貨周期 | 現(xiàn)貨 |
應用領域 | 環(huán)保,食品,生物產業(yè),農業(yè) |
Hamilton PRP-X100 Hamilton食品總砷無機砷檢測陰離子液相色譜柱79433/79448
Hamilton PRP-X100 聚合物 HPLC 色譜柱用于分離離子色譜中的陰離子
Hamilton PRP-X100 HPLC 色譜柱
Hamilton PRP-X100 HPLC Column
10 μm particle size, L × I.D. 25 cm × 4.1 mm, stainless steel hardware
application(s) | HPLC: suitable |
L × I.D. | 25 cm × 4.1 mm |
matrix | PS-DVB particle platform |
matrix active group | ammonium ion, quaternary phase |
particle size | 10 μm |
pore size | 100 ? |
separation technique | anion exchange |
產品各項參數(shù)描述:
Stationary Phase | PRP-X100 |
Mode | Anion Exchange |
Packing Material Type | PSDVB/Trimethylammonium |
Particle Size | 10 μm |
Pore Size | 100 ? |
Format | Column |
Hardware Inner Diameter | 4.1 mm |
Hardware Length | 250 mm |
Hardware Material | Stainless Steel |
Max. Pressure (bar g) | 5,000 psi |
Exchange Capacity | 0.19 meq/gm |
Exchange Capacity/Col | 0.304 meq/column |
Mob-ile Phase Limits | pH 1-13. 0-100% aqueous, organic modifier |
Buffer Strength | 0.0-0.5N |
Temp Limits | pH 179 560C pH 813 530C |
Restoration | Pump approximately 50 mL of methanol with 1% 6 N nitric acid. |
Compound Classification | Organic/Inorganic Anions |
UOM | 1 EACH |
應用:無機和有機陰離子的分離和純化
孔徑:100 ?
pH穩(wěn)定范圍:pH 1-13
可輕松分離8種常見離子
可分離自來水中氟
使用0-100%的有機溶劑進行疏水性陰離子的洗脫或清洗柱子
使用電導率或UV檢測器
3種粒子尺寸:5/10/12-20 μm
8種柱子的直徑:1.0-50.8 mm
2種柱子材料:316不銹鋼和PEEK
分析柱和制備/半制備保護柱
分離效果:
1. 常見陰離子(氟、氯、溴、碘)
2. 非直接UV檢測器檢測的陰離子
3. EDTA
4. 有機酸(甲酸、fu乙酸、膦酸、1111)
5. Germall 115
6. 溴酸鹽和其它陰離子
7. 硫酸鹽和亞硫酸鹽
8. 磷酸鹽和磷酸
9. 氯酸鹽
訂貨信息:
訂貨號 | 規(guī)格描述 | 柱管材質 | ||
79852 | PRP-X100, 5um, 2.1x150mm | PEEK | ||
79190 | PRP-X100, 5um, 2.1x250mm | S S | ||
79810 | PRP-X100, 5um, 4.1x50mm | S S | ||
79538 | PRP-X100, 5um, 4.1x100mm | S S | ||
79812 | PRP-X100, 5um, 4.1x150mm | S S | ||
79174 | PRP-X100, 5um, 4.6x150mm | PEEK | ||
79181 | PRP-X100, 5um, 4.6x250mm | PEEK | ||
79421 | PRP-X100, 10um,2.1x150mm | S S | ||
79346 | PRP-X100, 10um,2.1x250mm | S S | ||
79365 | PRP-X100, 10um, 4.1x50mm | S S | ||
79439 | PRP-X100, 10um, 4.1x100mm | S S | ||
79434 | PRP-X100, 10um, 4.1x150mm | S S | ||
79433 | PRP-X100, 10um, 4.1x250mm | S S | ||
79354 | PRP-X100, 10um, 4.6x150mm | PEEK | ||
79455 | PRP-X100, 10um, 4.6x250mm | PEEK | ||
79353 | PRP-X100, 12-20um, 21.2x250mm | S S | ||
79448 | Guard column Starter Kit(1 holder,2 cartridges) | S S | ||
79446 | Replacement Cartridges(5/pk) | S S | ||
79383 | Guard column Starter Kit(1 holder,2 cartridges) | PEEK | ||
79385 | Replacement Cartridges(5/pk) | PEEK |
不銹鋼保護柱芯的尺寸: 2.3x20mm, PEEK保護柱芯的尺寸: 3.0x8.0mm
保護柱芯(貨號79446,5只/包)
保護柱套裝(1柱套2柱芯,貨號79448)
···································································
常見以下幾種情況:色譜峰拖尾、色譜峰分裂、色譜峰擴展,許多色譜峰峰形問題都是復合型問題, 造成色譜峰擴展和柱效降低;色譜峰擴展和拖尾或拖尾隨保留加劇。從以下幾個方面色譜柱問題、溶劑效應、進樣量(過載)、樣品的特性、柱外效應來分析。
1、色譜柱問題
污物在柱進口處積聚-強溶劑沖洗柱子
二次保留效應-加入掃尾劑,10mM的TEA
重金屬污染-使用高純硅膠基質色譜柱
對于難溶解的物質:小體積強溶劑溶解以后用MP稀釋,掃尾劑:30mM的TEA(B性化合物),醋酸胺(A性化合物)不加TEA 10mM的TEA
ASB C18,4.6×150mm,5µm,85% 25mM NaH2Na,15%ACN 1mL/min, 35℃
硅膠純度
初始的硅膠基質,酸洗后的硅膠基質,流動相:20mM三11因強調分析速度而發(fā)展出短柱,柱長3~10cm,填料粒徑2~3µm。為提高分析靈敏度,與質譜(MS)聯(lián)接,而發(fā)展出窄徑柱、毛細管柱和內徑小于0.2mm的微徑柱(microbore)。細管徑柱的優(yōu)點是:①節(jié)省流動相;②靈敏度增加;③樣品量少;④能使用長柱達到高分離度;⑤容易控制柱溫;⑥易于實現(xiàn)LC-MS聯(lián)用。
但由于柱體積越來越小,柱外效應的影響就更加顯著,需要更小池體積的檢測器(甚至采用柱上檢測),更小死體積的柱接頭和連接部件。配套使用的設備應具備如下性能:能精密輸出1~100µl/min的低流量,進樣閥能準確、重復地進樣微小體積的樣品。且因上樣量小,要求高靈敏度的檢測器,電化學檢測器和質譜儀在這方面具有突出優(yōu)點。
采用316不銹鋼或者PEEK為柱材料;
可用于分析,半制備/制備色譜柱及其保護柱;
粒徑3,5,7,10,12-20微米等多種選擇;
柱內徑從1-101毫米;
聚合物基質填充原料
穩(wěn)定的 pH 范圍 1-13
*的壓力穩(wěn)定性
柱壽命長
用于生物高分子分析的 300A 色譜柱
在選擇色譜柱之前,先多了解自己的樣品和雜質,他們的類型結構、極性、酸堿性、分子量大小等等,
1.樣品是極性的且弱酸性的;就可以選擇C18在100%酸性水溶液條件下檢測,即要選擇承受100%純水且對極性化合物保留很好的色譜柱
2. 如果樣品極性太強,或酸性太強;可以選擇CN,NH2,或硅膠柱,HILIC(親水色譜),也有使用C18+強陰離子對試劑或強陰離子交換色譜柱(缺點是離子對試劑平衡時間長,對流動相pH要求比較精密,否 則很難重復實驗,另外離子對試劑很難洗下來,基本上用了離子對的色譜柱就不能再用于其它實驗)
3. 若樣品是堿性的;可選擇高純硅膠柱(高純硅膠缺少金屬雜質,且硅膠端基封尾)或一些經過修飾的C18柱(如極性嵌入技術或堿去活技術等),他們都會減少堿性化合物的拖尾,一般會選擇中性或偏堿的條件下做,因為這樣可增加堿性樣品的保留
4.如果堿性化合物的極性太強,或堿性太強;可以選擇寬pH的C18色譜柱在高pH值檢測(優(yōu)點是方法開發(fā)簡單,缺點是目前實 現(xiàn)這一技術的色譜柱品牌比較少,價格也高)或者選用HILIC色譜柱(硅膠柱在反相條件下使用,這也是很經典的檢測堿性樣品的方法)選擇強離子交換柱(缺點 是不能用來分析其它樣品,對流動相pH要求比較精密,否則很難重復實驗)也有使用C18+強陰離子對試劑或強陰離子交換色譜柱。